无组织废气中的三甲胺测定专用毛细管柱HH-Tamine60
  • 无组织废气中的三甲胺测定专用毛细管柱HH-Tamine60

  • 发布时间:2024-12-22 10:19:42
  • 产品简介:
    名称:HH-Tamine60甲胺专用毛细管柱
    规格:60m*0.32mm*5.0um
    最高使用温度:280°C
    编号:20230319001
    应用:固定污染源废气中三甲胺的测定 气相色谱法
咨询热线:0632-5667636

浩瀚色谱(山东)应用技术开发有限公司用弱酸性吸收液采集无组织废气中的三甲胺,加入碱液后,在一定的温度下经一定时间的平衡,吸收液中的三甲胺逸至上部空间,并在气液两相中达到动态的平衡。此时,三甲胺在气相中的浓度与它在液相中的浓度成正比。用氢火焰离子化检测器对气相中的三甲胺进行测定。实验结果表明,在无组织废气吸收液体积为10.0 mL,采样体积为20 L时,三甲胺的检出限是0.003 mg/m~3,线性良好,相关系数为0.9997,加标回收率为85.0%-100%。初步建立了顶空气相色谱法测定无组织废气中三甲胺的方法。

 

名称:HH-Tamine60甲胺专用毛细管柱

规格:60m*0.32mm*5.0um

最高使用温度:280°C

编号:20230319001

应用:固定污染源废气中三甲胺的测定 气相色谱法

适用于安捷伦,岛津,赛默飞,瓦里安,布鲁克,PE等

 

甲烷转化炉甲烷转化炉5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱

 

 

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. collects trimethylamine from unorganized waste gas using weakly acidic absorption solution. After adding alkaline solution, the trimethylamine in the absorption solution escapes to the upper space at a certain temperature and reaches dynamic equilibrium in the gas-liquid phase after a certain period of time. At this point, the concentration of trimethylamine in the gas phase is proportional to its concentration in the liquid phase. Use a hydrogen flame ionization detector to determine trimethylamine in the gas phase. The experimental results showed that when the volume of unorganized exhaust gas absorption solution was 10.0 mL and the sampling volume was 20 L, the detection limit of trimethylamine was 0.003 mg/m3, with good linearity and a correlation coefficient of 0.9997. The spiked recovery rate was 85.0% -100%. A preliminary method for determining trimethylamine in unorganized waste gas using headspace gas chromatography has been established.
Name: HH Tamine60 Methylamine Specific Capillary Column
Specification: 60m * 0.32mm * 5.0um
Maximum operating temperature: 280 ° C
Number: 20230319001
Application: Determination of Trimethylamine in Fixed Source Waste Gas by Gas Chromatography
Suitable for Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, PE, etc

联系人
手机号码
电子邮件
验证码
看不清楚?点击换张图片
我要评论:

(内容最多500个汉字,1000个字符)

验 证 码 :
提交信息

网站首页  |  产品展示  |  关于我们  |  新闻资讯  |  技术服务  |  营销招聘  |  公司资质  |  联系我们

网站ICP备案号:鲁ICP备18012860号

鲁公网安备: 37048102006522号

浩瀚色谱(山东)应用技术开发有限公司
地址:山东滕州市平行路(商务部和技术部)
电话:0632-5667636   传真:0632-5667636
手机:15562228838,13963221227  邮箱:wangxiaoying9@126.com

 

技术支持:牵牛建站 | 中科商务网  | 网站管理