20%PEG-20M/GCS880 AW DMCS填充柱测定乙醛应用安捷伦岛津
  • 20%PEG-20M/GCS880 AW DMCS填充柱测定乙醛应用安捷伦岛津

  • 发布时间:2024-12-22 10:17:39
  • 产品简介:
    名称:不锈钢填充柱
    规格:2m*3mm
    型号:20%PEG-20M/GCS880 AW DMCS
    编号:20240812006
    最高温度:240°C
咨询热线:0632-5667636

为改善直接进样法中高浓度盐对进样口、色谱柱和检测器的污染,降低检出限。浩瀚色谱建立了顶空气相色谱法测定空气和废气中乙醛的方法,并对色谱条件和顶空进样条件进行了优化。结果:该方法的检出限1.0μg,当采样体积为100 L时,方法检出浓度为0.01 mg/m3,室内相对标准偏差为1.6%~5.0%,加标回收率为95.2%~101.0%。结论:该方法有效地避免了直接进样法中高浓度盐对进样口、色谱柱乃至检测器的污染,并且大大降低了检出限,方法的可靠性和可操作性令人满意。

 

本标准适用于固定污染源有组织排放和无组织排放的乙醛测定。当采样条件为100L,进样条件为1μl时,乙醛的检出限为4×10-2mg/m3,乙醛的定量测定浓度范围为0.14mg/m3~30mg/m3。
名称:不锈钢填充柱
规格:2m*3mm
型号:20%PEG-20M/GCS880 AW DMCS
编号:20240812006
*高温度:240°C
应用:HJ/T 35-1999 固定污染源排气中乙醛的测定 气相色谱法
适用于安捷伦,岛津,赛默飞,瓦里安,布鲁克,PE,磐诺,天瑞,天美,北分瑞利,东西电子,福立

5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱

 

To improve the contamination of the injection port, chromatographic column, and detector by high concentration salts in direct injection method and reduce the detection limit. Haohan Chromatography has established a headspace gas chromatography method for the determination of acetaldehyde in air and exhaust gas, and optimized the chromatographic and headspace injection conditions. Result: The detection limit of this method is 1.0 μ g. When the sampling volume is 100 L, the detected concentration of the method is 0.01 mg/m3, the indoor relative standard deviation is 1.6%~5.0%, and the spiked recovery rate is 95.2%~101.0%. Conclusion: This method effectively avoids contamination of the injection port, chromatographic column, and even detector by high concentration salts in direct injection method, and greatly reduces the detection limit. The reliability and operability of the method are satisfactory.
This standard is applicable to the determination of acetaldehyde in organized and unorganized emissions from fixed pollution sources. When the sampling condition is 100L and the injection condition is 1 μ l, the detection limit of acetaldehyde is 4 × 10-2mg/m3, and the quantitative determination concentration range of acetaldehyde is 0.14mg/m3 to 30mg/m3.
Name: Stainless Steel Filled Column
Specification: 2m * 3mm
Model: 20% PEG-20M/GCS880 AW DMCS
Number: 20240812006
*High temperature: 240 ° C
Application: HJ/T 35-1999 Determination of Acetaldehyde in Fixed Source Exhaust Gas Gas Chromatography Method
Suitable for Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, PE, Panno, Tianrui, Tianmei, Beifen Ruili, Dongxi Electronics, Fuli

联系人
手机号码
电子邮件
验证码
看不清楚?点击换张图片
我要评论:

(内容最多500个汉字,1000个字符)

验 证 码 :
提交信息

网站首页  |  产品展示  |  关于我们  |  新闻资讯  |  技术服务  |  营销招聘  |  公司资质  |  联系我们

网站ICP备案号:鲁ICP备18012860号

鲁公网安备: 37048102006522号

浩瀚色谱(山东)应用技术开发有限公司
地址:山东滕州市平行路(商务部和技术部)
电话:0632-5667636   传真:0632-5667636
手机:15562228838,13963221227  邮箱:wangxiaoying9@126.com

 

技术支持:牵牛建站 | 中科商务网  | 网站管理