联系我们

 

联系我们

浩瀚色谱(山东)应用技术开发有限公司
电话:0632-5667636
传真:0632-5667636
手机:15562228838,13963221227

地址:山东滕州市平行路(商务部和技术部)
邮箱:wangxiaoying9@126.com
QQ:1404939462
联系人:王经理
网址:www.haohansepu.com

聚乙二醇毛细管环境空气和废气 三jia苯
  • 聚乙二醇毛细管环境空气和废气 三jia苯

  • 发布时间:2024-12-22 10:10:25
  • 产品简介:
    环境空气和废气 三甲苯的测定,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,变压器油,三甲胺,采样管,吸附剂
咨询热线:0632-5667636

固定污染源废气的采样应符合中的相关规定。采样时敲开活性炭采样管的两端,与烟气采样器相连(A段为气体入口),检查采样系统的气密性,检查方法和标准按照HJ/T 397要求执行。以0.2 L/min~1.0 L/min的采样流量,连续采样1 h,或在1 h内以等时间间隔采集3~4个样品计平均值,采样时间一般不少于10 min。若废气中湿度太大,以致在活性炭管中凝结时,必须在烟气采样枪和活性炭采样管之间加装除湿装置,并伴热以除去水汽对活性炭采样管的影响。

 

本标准规定了环境空气和废气中三甲苯(1,3,5-三甲苯、1,2,4-三甲苯和1,2,3-三甲苯)测定的活性炭吸附/二硫化碳解吸-气相色谱法。
本标准适用于环境空气以及木质家具制造业、汽车制造和维修业等有组织和无组织排放废气中三甲苯的测定,其他行业废气经验证后也可使用本方法。
对于环境空气,当采样体积为30 L时,本方法检出限为0.004 mg/m3~0.006 mg/m3,测定下限为0.016 mg/m3~0.024 mg/m3;对于废气,当采样体积为10 L时,本方法检出限均为0.02 mg/m3,测定下限均为0.08 mg/m3,详见附录A。

 

 

名称:聚乙二醇毛细管柱

型号:PEG-20M

规格:30m*0.32mm*1.0um

温度:240°C

 

 

5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱5A分子筛填充柱

 

The sampling of exhaust gas from fixed pollution sources should comply with the relevant regulations in. When sampling, open both ends of the activated carbon sampling tube and connect it to the flue gas sampler (section A is the gas inlet) to check the airtightness of the sampling system. The inspection method and standard should be carried out in accordance with the requirements of HJ/T 397. Sample continuously for 1 hour at a sampling flow rate of 0.2 L/min to 1.0 L/min, or collect 3-4 samples at equal time intervals within 1 hour to calculate the average value. The sampling time is generally not less than 10 minutes. If the humidity in the exhaust gas is too high to condense in the activated carbon tube, a dehumidification device must be installed between the flue gas sampling gun and the activated carbon sampling tube, and heat tracing must be carried out to remove the influence of water vapor on the activated carbon sampling tube.

This standard specifies the activated carbon adsorption/Carbon disulfide desorption gas chromatography method for the determination of trimethylene (1,3,5-trimethylene, 1,2,4-trimethylene and 1,2,3-trimethylene) in ambient air and waste gas.

This standard is applicable to the determination of trimethylbenzene in environmental air, as well as in organized and unorganized exhaust gases from wood furniture manufacturing, automotive manufacturing, and maintenance industries. This method can also be used after verification in other industries' exhaust gases.

For ambient air, when the sampling volume is 30 L, the detection limit of this method is 0.004 mg/m3 to 0.006 mg/m3, and the detection limit is 0.016 mg/m3 to 0.024 mg/m3; For exhaust gas, when the sampling volume is 10 L, the detection limit of this method is 0.02 mg/m3, and the lower limit of determination is 0.08 mg/m3. Please refer to Appendix A.

Name: Polyethylene glycol capillary column

Model: PEG-20M

Specification: 30m * 0.32mm * 1.0um

Temperature: 240 ° C

联系人
手机号码
电子邮件
验证码
看不清楚?点击换张图片
我要评论:

(内容最多500个汉字,1000个字符)

验 证 码 :
提交信息

网站首页  |  产品展示  |  关于我们  |  新闻资讯  |  技术服务  |  营销招聘  |  公司资质  |  联系我们

网站ICP备案号:鲁ICP备18012860号

鲁公网安备: 37048102006522号

浩瀚色谱(山东)应用技术开发有限公司
地址:山东滕州市平行路(商务部和技术部)
电话:0632-5667636   传真:0632-5667636
手机:15562228838,13963221227  邮箱:wangxiaoying9@126.com

 

技术支持:牵牛建站 | 中科商务网  | 网站管理