HH-THC-30总烃脱活毛细管柱
  • HH-THC-30总烃脱活毛细管柱

  • 发布时间:2024-12-22 10:8:24
  • 产品简介:
    固定污染源废气,环境空气,医疗器械,环氧乙烷,芝麻香白酒,3-甲硫基丙醇,变压器油溶解气,氨水,氨气,三甲胺,MTBE,TENAX-TA,吸附剂,采样管,增塑剂,塑化剂
咨询热线:0632-5667636

浩瀚色谱(山东)应用技术开发有限公司采用十通阀、双定量环进样,分子筛的甲烷柱和HH-THC-30的脱活总烃毛细管空柱分别分离两路气样,单FID检测器检测的方法测定环境空气和固定污染源废气中的总烃和非甲烷总烃(NMHC)。实验结果表明:总烃与甲烷工作曲线的相关系数分别为0.997 7和0.999 0;总烃与甲烷测定结果的相对标准偏差均未超过1.5%;总烃与NMHC的检出限均为0.04 mg/m3;总烃的加标回收率为90.3%113.0%,NMHC的加标回收率为91.1%110.0%。上述指标均满足HJ 604—2011和HJ/T 38—1999中对总烃及NMHC的测定要求,

HJ 604-2017 环境空气 总烃、甲烷和非甲烷总烃的测定 直接进样-气相色谱法,HJ 38-2017 固定污染源废气 总烃、甲烷和非甲烷总烃的测定 气相色谱法。

 

名称:脱活毛细管柱

货号:HHTH3005001

型号:HH-THC-30

规格:30m*0.53mm

zui高使用温度:300°C

编号:20230513003

应用:HJ 604-2017 环境空气 总烃、甲烷和非甲烷总烃的测定 直接进样-气相色谱法


HJ 38-2017 固定污染源废气 总烃、甲烷和非甲烷总烃的测定 气相色谱法

 

气相色谱仪气相色谱仪气相色谱仪气相色谱仪气相色谱仪

 

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses a ten way valve, dual quantitative ring injection, molecular sieve methane column, and HH-THC-30 deactivated total hydrocarbon capillary space column to separate two gas samples, and a single FID detector detection method to determine total hydrocarbons and non methane total hydrocarbons (NMHC) in ambient air and fixed pollution source exhaust gas. The experimental results show that the correlation coefficients between the working curves of total hydrocarbons and methane are 0.997 7 and 0.999 0, respectively; The relative standard deviation of total hydrocarbon and methane determination results does not exceed 1.5%; The detection limit for total hydrocarbons and NMHC is 0.04 mg/m3; The spiked recovery rate of total hydrocarbons is 90.3% to 11.30%, and the spiked recovery rate of NMHC is 91.1% to 11.0%. The above indicators meet the determination requirements for total hydrocarbons and NMHC in HJ 604-2011 and HJ/T 38-1999,

HJ 604-2017 Determination of total hydrocarbons, methane, and non-methane in ambient air - Direct injection gas chromatography method, HJ 38-2017 Determination of total hydrocarbons, methane, and non-methane in fixed source exhaust gas - Gas chromatography method.

Name: Deactivated capillary column

Article number: HHTH3005001

Model: HH-THC-30

Specification: 30m * 0.53mm

Zui High usage temperature: 300 ° C

No.: 20230513003

Application: HJ 604-2017 Determination of total hydrocarbons, methane, and non methane total hydrocarbons in ambient air - Direct injection gas chromatography method


HJ 38-2017 Determination of Total Hydrocarbons, Methane, and Non methane Total Hydrocarbons in Waste Gas from Fixed Pollution Sources - Gas Chromatography Method

联系人
手机号码
电子邮件
验证码
看不清楚?点击换张图片
我要评论:

(内容最多500个汉字,1000个字符)

验 证 码 :
提交信息

网站首页  |  产品展示  |  关于我们  |  新闻资讯  |  技术服务  |  营销招聘  |  公司资质  |  联系我们

网站ICP备案号:鲁ICP备18012860号

鲁公网安备: 37048102006522号

浩瀚色谱(山东)应用技术开发有限公司
地址:山东滕州市平行路(商务部和技术部)
电话:0632-5667636   传真:0632-5667636
手机:15562228838,13963221227  邮箱:wangxiaoying9@126.com

 

技术支持:牵牛建站 | 中科商务网  | 网站管理